10.3 Filters and Signal Conditioning Circuits

3 min readaugust 7, 2024

Filters and signal conditioning circuits are crucial in biomedical instrumentation. They clean up and enhance physiological signals, making them easier to analyze. From low-pass filters that remove high-frequency noise to that amplify weak signals, these tools are essential for accurate measurements.

Signal conditioning techniques like and optimize signals for further processing. These methods are vital in various medical applications, ensuring that important data from ECGs, EEGs, and other biomedical sensors is clear and reliable for diagnosis and monitoring.

Filters

Frequency-Based Filtering

Top images from around the web for Frequency-Based Filtering
Top images from around the web for Frequency-Based Filtering
  • allows frequencies below the to pass through while attenuating higher frequencies
  • allows frequencies above the cut-off frequency to pass through while attenuating lower frequencies
  • allows a specific range of frequencies to pass through while attenuating frequencies outside the specified range (bandwidth)
  • , also known as a band-stop filter, attenuates a specific range of frequencies while allowing frequencies outside the specified range to pass through

Filter Characteristics

  • Cut-off frequency defines the boundary between the passband and the stopband of a filter
    • Frequencies within the passband are allowed to pass through the filter with minimal
    • Frequencies within the stopband are significantly attenuated by the filter
  • refers to the rate at which the filter attenuates frequencies beyond the cut-off frequency
    • Measured in decibels per octave (dB/octave) or decibels per decade (dB/decade)
    • Steeper roll-off results in a sharper transition between the passband and the stopband (Butterworth, Chebyshev)
    • Gradual roll-off provides a more gentle transition between the passband and the stopband (Bessel)

Filter Types

Active Filters

  • Active filters incorporate active components such as operational amplifiers (op-amps) along with passive components (resistors, capacitors)
  • Provide and buffering, allowing for improved filter performance and impedance matching
  • Require a power supply to operate the active components
  • Offer greater design flexibility and the ability to achieve higher-order filter responses (, )

Passive Filters

  • consist solely of passive components such as resistors, capacitors, and inductors
  • Do not require a power supply as they do not contain active components
  • Offer simplicity and low noise performance but may suffer from signal attenuation and impedance matching issues
  • Commonly used in applications where signal amplification is not required (, , )

Signal Conditioning

Signal Conditioning Techniques

  • Signal conditioning involves manipulating and processing signals to optimize them for further analysis or transmission
  • Amplitude scaling adjusts the amplitude of a signal to match the input range of the next stage in the signal processing chain
    • Amplification increases the signal amplitude to improve (SNR) and resolution
    • Attenuation reduces the signal amplitude to prevent overloading or saturation of subsequent stages
  • Impedance matching ensures proper signal transfer between different stages of a signal processing system
    • Minimizes signal reflections and power loss due to impedance mismatches
    • Achieved using , , or impedance-matching networks (, )

Signal Conditioning Applications

  • Signal conditioning is essential in various domains, including biomedical instrumentation, industrial control systems, and data acquisition systems
  • In biomedical instrumentation, signal conditioning is used to process and enhance physiological signals such as ECG, EEG, and EMG
    • Filters remove noise and interference from the signals
    • Amplifiers boost the low-amplitude signals for accurate measurement and analysis
  • In industrial control systems, signal conditioning is employed to interface sensors and actuators with control systems
    • Scaling and normalization of sensor outputs to match the input range of control systems
    • Isolation and protection of sensitive control circuitry from high-voltage or noisy environments
© 2024 Fiveable Inc. All rights reserved.
AP® and SAT® are trademarks registered by the College Board, which is not affiliated with, and does not endorse this website.


© 2024 Fiveable Inc. All rights reserved.
AP® and SAT® are trademarks registered by the College Board, which is not affiliated with, and does not endorse this website.

© 2024 Fiveable Inc. All rights reserved.
AP® and SAT® are trademarks registered by the College Board, which is not affiliated with, and does not endorse this website.
Glossary
Glossary